For direct control of drives up to 8.8 HP
For direct control of drives up to 8.8 HP
DSK control pendants
DSK control pendants
Convenient control
Whether you need to control hoists or machinery, wire-connected DSK control pendants are the ideal solution.
- High level of safety
- For direct or contactor control
- Ergonomic design and operation
- Can be configured to meet a wide range of specific needs
Your Contact
Demag Cranes & Components Corp.
Demag Cranes & Components Corp.
6675 Parkland Blvd., Suite 200
Cleveland, Ohio 44139
United States
Product information
The benefits at a glance
High safety and reliability
- Mechanical interlocking of the switching elements
- Movements in opposite directions cannot be simultaneously actuated
Performance to meet application requirements
- Direct control of drives with motor outputs up to 8.8 HP (5.5 kW) by using various switching elements
- Indirect control using contactors in the auxiliary circuit for higher outputs
Convenient operation
- Easy operation due to ergonomical housing design
- Sloping control pendant design permits operators to work in a natural, comfortable posture
Customizable
- Can be configured to customer specifications (e.g. cable length)
Technical data
DSK series control pendants offer the following outstanding technical details:
- Permissible ambient temperatures from -13 °F to +158 °F
Safety
- Strain relief by means of special hose with additional protective sleeve, as standard
- Protective insulation to DIN VDE 0100 Part 410
- Switching distances and forces to DIN 33401, holding force < 1.8 lb (8 N)
- IP 55 enclosure to DIN VDE 0470 as standard in "suspended" operating position
- IP65 on request
Control
- CBDN switching element (emergency stop) with positive opening of the NC contacts
- Direct control of drives up to 8.8 HP (5.5 kW)
- Simultaneous 2-pole switching for direct control
- Switching elements for direct or contactor control
Housing
- High-quality thermoplastic housing that is highly resistant to impacts
- Non-flammable, climate and corrision-proof
- Highly resistant to fuels, salt water, grease, oils and alkaline solutions
Main current switching elements | ||||||
---|---|---|---|---|---|---|
Type | CBD 1 | CBD 2 | CBDN | |||
Design | Single-stage switching element 2 NO |
Double-stage switching element 2 NO in the 1st stage 2 changeover contacts in the 2nd stage |
Single-stage crane switch (emergency stop), 3 NC |
|||
Rated operating voltage [V] | 230 | 400 | 500 | 230 | 400 | 500 |
Rated operating current [A] | 20 | 12 | 9 | Ith 2 | 25 | |
Utilisation category to DIN VDE 0660 / EN 60947 Main current |
AC 3, AC 4 | AC 3, AC 4 | for breaking capacity up to 5.5 kW | |||
Nominal insulation voltage | Ui 500 V~ to DIN VDE 0110, CSA 300 VAC |
Control current switching element | ||||||
---|---|---|---|---|---|---|
Type | CBS 1 | CBS 2 | ||||
Design | Single-stage switching element 2 NO |
Double-stage switching element 2 NO in the 1st stage 1 sequence-controlled NO in the 2nd stage |
||||
Rated operating voltage [V] | 230 | 400 | 500 | 230 | 400 | 500 |
Rated operating current [A] | 10 | 6 | 4.5 | 10 | 6 | 4.5 |
Utilisation category to DIN VDE 0660 / EN 60947 Main current |
AC 15 | AC 15 | ||||
Nominal insulation voltage | Ui 500 V~ to DIN VDE 0110, CSA 150 V AC |